B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 209 -
#7 #6 #5 #4 #3 #2 #1 #0
NVG F2K TPA DDS POR
3119
NVG TPA DDS POR
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
POR Display in Portuguese is:
0 : Disabled.
1 : Enabled.
DDS When the touch panel control option is available, the touch panel is:
0 : Enabled.
1 : Disabled.
TAP When the external touch panel interface option is available, the
external touch panel is:
0 : Enabled.
1 : Disabled.
F2K As the LCD/MDI keyboard, Symbol CAPi T (CAP-II) combined with
a unified standard keyboard is:
0 : Not used.
1 : Used.
NVG When a color display device is used, VGA mode is:
0 : Used.
1 : Not used. (Conventional type)
3120
Time from the output of an alarm to the termination of sampling (waveform
diagnosis function)
[Data type] Word
[Unit of data] msec
[Valid data range] 1 to 32760
When the waveform diagnosis function is used, this parameter sets the
time form the output of a servo alarm until data collection. Storage
operation is stopped because of the alarm. (This means that the
termination of data collection can be delayed by a specified time.)
3121
Selection of waveform diagnosis data of storage type (waveform diagnosis
function)
[Data type] Byte
[Valid data range] 0 to 1
The sixth type of sampling data collected by waveform diagnosis of
storage type is:
0 : Heat simulation data
1 : Spindle load meter