4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 416 -
#7 #6 #5 #4 #3 #2 #1 #0
6010 *7 *6 *5 *4 *3 *2 *1 *0
#7 #6 #5 #4 #3 #2 #1 #0
6011 =7 =6 =5 =4 =3 =2 =1 =0
#7 #6 #5 #4 #3 #2 #1 #0
6012 #7 #6 #5 #4 #3 #2 #1 #0
#7 #6 #5 #4 #3 #2 #1 #0
6013 [7 [6 [5 [4 [3 [2 [1 [0
#7 #6 #5 #4 #3 #2 #1 #0
6014 ]7 ]6 ]5 ]4 ]3 ]2 ]1 ]0
[Data type] Bit
These parameters are used for input/output with EIA codes.
The numeral of a suffix indicates the bit position in a code.
*0 to *7 : Set the hole pattern of an EIA code indicating *.
=0 to =7 : Set the hole pattern of an EIA code indicating =.
#0 to #7 : Set the hole pattern of an EIA code indicating #.
[ 0 to [ 7 : Set the hole pattern of an EIA code indicating [.
] 0 to ] 7 : Set the hole pattern of an EIA code indicating ].
0 : Corresponding bit is 0
1 : Corresponding bit is 1.
6030 M code that calls the program entered in file
[Data type] 2-word
[Valid data range] 0, 1 to 255
This parameter sets an M code that calls the program entered in a file.
NOTE
The M code is judged to be M198 when 0 is
specified as the setting value.
6033 M code that validates a custom macro interrupt
6034 M code that invalidates a custom macro interrupt
[Data type] 2-word
[Valid data range] 0 to 255
These parameters set the custom macro interrupt valid/invalid M
codes.
NOTE
These parameters can be used when bit 4 (MPR)
of parameter No.6003 is set to 1. M96 is used as a
valid M code and M97 is used as an invalid M code
when bit 4 (MPR) of parameter No.6003 is set to 0,
irrespective of the state of these parameters.