ATS Automatic setting of grid positioning for simple synchronous control
(one pair) is:
0 : Not started
1 : Started
NOTE
1 When the bits are set to 1, bit 4 (APZx) of
parameter No.1815 and parameter No.8316 for the
master and slave axes are set to 0.
2 These bits are automatically set to 0 once grid
positioning has been completed.
SSE In simple synchronous control, the external machine coordinate
system shift function for the slave axis is:
0 : Not used.
1 : Used.
For axes under simple synchronous control, when the external
machine coordinate system shift is performed for the master axis, it
can also performed for the slave axis simultaneously.
NOTE
The simple synchronous signal must be
manipulated.
Carefully turn the simple synchronous signal on
and off because the machine may move at that
time.
SMA When bit 4x (APZx) of parameter No. 1015 is turned off for one axis
under simple synchronous control, APZx for the other axis under
simple synchronous control is:
0 : Not turned off.
1 : Turned off.
When an axis for which the simple synchronous axis parameter is set
is under simple synchronous control, the simple synchronous signal is
turned on for the axis.
#7 #6 #5 #4 #3 #2 #1 #0
8303
SOFx ATSx ATEx
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit axis
ATEx In simple synchronous control, automatic setting for grid positioning
is:
0 : Disabled.
1 : Enabled.