B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 65 -
Address number of the internal relay (R signal) of the PMC for signal output
of the first reference position
1245
Address number of the internal relay (R signal) of the PMC for signal output
of the second reference position
1246
[Data type] Word
[Unit of data] 0 to 66535
Set the address number of the R signal for signal output of the
first/second reference position. If the address number of a nonexistent
R signal is set in any of these parameters, the reference position signal
output function is disabled.
See the descriptions of bit 4 (R1O) and bit 5 (R2O) of parameter No.
1205.
1250
Coordinate value of the reference position used when automatic coordinate
system setting is performed
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Linear axis (input in mm) 0.01 0.001 0.0001 mm
Linear axis (input in inches) 0.001 0.0001 0.00001 inch
Rotary axis 0.01 0.001 0.0001 deg
[Valid data range] -99999999 to 99999999
Set the coordinate value of the reference position on each axis to be
used for setting a coordinate system automatically.
1251
Coordinate value of the reference position on each axis used for setting a
coordinate system automatically when input is performed in inches
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Linear axis (input in inches) 0.001 0.0001 0.00001 inch
[Valid data range] -99999999 to 99999999
Set the coordinate value of the reference position on each axis to be
used for setting a coordinate system automatically when input is
performed in inches.
NOTE
This parameter is valid when bit 1 (ZPI) of
parameter No. 1201 is set to 1.