4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 20 -
0133 Baud rate (when the I/O CHANNEL is set to 3)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Byte
Set the baud rate of the input/output device used when the I/O
CHANNEL is set to 3 according to the table 4.2.5.
Valid data range: 1 to 15 (up to a baud rate of 86400 bps) for the
RS-422 interface or 1 to 12 (up to a baud rate of 19200 bps) for the
RS-232C interface.
Table 4.2.5
Set value Baud rate (bps) Set value Baud rate (bps)
1 50 9 2400
2 100 10 4800
3 110 11 9600
4 150 12 19200
5 200 13 38400
6 300 14 76800
7 600 15 86400
8 1200
#7 #6 #5 #4 #3 #2 #1 #0
0134 CLK NCD SYN PRY
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
PRY Parity bit
0 : Not used
1 : Used
SYN Reset/alarm in protocol B
0 : Not reported to the host
1 : Reported to the host with SYN and NAK codes
NCD CD (signal quality detection) of the RS-232C interface
0 : Checked
1 : Not checked
CLK Baud rate clock when the RS-422 interface is used
0 : Internal clock
1 : External clock
NOTE
When the RS-232C interface is used, set this bit to
0.