B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 581 -
4.69 PARAMETERS OF SEQUENCE NUMBER COMPARISON
AND STOP
8341 Program number subject to comparison and stop
This parameter can also be set on the “Setting screen”.
[Data type] Word
[Valid data range] 0 to 9999
This parameter sets the program number, including a sequence number,
subject to sequence number comparison and stop. Parameter No.8342
is used to set a sequence number subject to check termination.
NOTE
A program number can also be set on the setting
screen. If a program number is set on the setting
screen, the value of the parameter is changed
accordingly.
8342 Sequence number subject to comparison and stop
This parameter can also be set on the “Setting screen”.
[Data type] 2-word
[Valid data range] 0 to 9999
This parameter sets the sequence number subject to sequence number
comparison and stop.
If the block containing the sequence number set with this parameter is
executed while the program set with parameter No.8341 is being
executed, a single block stop occurs after the block is executed. At this
time, the setting is automatically set to 1. Upon power-up, the setting
is automatically set to 0.
NOTE
A program number can also be set on the setting
screen. If a sequence number is set on the setting
screen, the value of the parameter is changed
accordingly.
8343
Program number subject to comparison and stop (when an 8-digit program
number is used)
This parameter can also be set on the “Setting screen”.
[Data type] 2-word
[Valid data range] 0 to 99999999
When a sequence number check is to be stopped, this parameter sets
the program number to which a sequence number where the check is
to be stopped belongs. Set a stop sequence number in parameter
No.8342.