4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 538 -
4.64 PARAMETERS OF INTERFERENCE CHECK BETWEEN
TWO TOOL POSTS (TWO-PATH) (FOR TWO-PATH
CONTROL)
#7 #6 #5 #4 #3 #2 #1 #0
ZCL IFE IFM ITO TY1 TY0
8140
IFE IFM
[Data type] Bit
TY0, TY1 This parameter specifies the relationship between the coordinate
systems of the two tool posts.
X
X
X
X
Z Z
Z
Z
(3) When TY1=1 and TY0=0 (4) When TY1=1 and TY0=1
Tool post 2
Tool post 1 Tool post 1
Tool post 2
(1) When TY1=0 and TY0=0 (2) When TY1=0 and TY0=1
X X
Z
X
ZZ
Tool post 1
Tool post 2
Tool post 2 Tool post 1
ITO When offset number 0 is specified by the T code,
0 : Interference check between two tool posts is stopped until an
offset number other than 0 is specified by the next T code.
1 : Interference check between two tool posts is continued according
to the previously specified offset number.
IFM In manual mode, an interference check between two tool posts (T
series) and interference check between two-path (M series) are:
0 : Not performed.
1 : Performed.
IFE An interference check between two tool posts (T series) and
interference check between two-path (M series) are:
0 : Performed.
1 : Not performed.
ZCL Specifies whether interference along the Z axis is checked while
interference check between two tool posts.
0 : Checked
1 : Not checked (Only interference along the X axis is checked.)