B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 247 -
#7 #6 #5 #4 #3 #2 #1 #0
3456
LSVx
[Data type] Bit axis
LSVx Slide axis control for link metho is:
0 : Not used.
1 : Used.
NOTE
1 When this parameter is set, the power must be
turned off before operation is continued.
2 Before the power is turned off after this parameter
is set, it is recommended to set the quadratic
expression coefficient parameters (No. 14981 to
No. 14983) and the deceleration ratio minimum
slide position parameter (No. 14984).
3 This control is exercised upon completion of
reference position setting.
4 When simple synchronous control is used, set this
parameter for both of the master axis and slave
axis.
3460
Address for second auxiliary function
[Data type] Byte
This parameter specifies the address used for the second auxiliary
function, as follows:
Axes names cannot be used to specify the address.
Address
A B C U V W
Set value
65 66 67 85 86 87
Address B is assumed when a value other than the above is set.
3471
Allowable difference between the specified end position and the end
position obtained from the increase/decrease and frequency in conical/spiral
interpolation
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range] 0 to 99999999
This parameter sets the maximum allowable difference (absolute
value) between the specified end position and the end position
obtained from the increase/decrease and frequency in conical/spiral
interpolation.