B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 253 -
3624 Interval between pitch error compensation positions for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotary axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
The pitch error compensation positions are arranged with equal
spacing. The space between two adjacent positions is set for each axis.
The minimum interval between pitch error compensation positions is
limited and obtained from the following equation:
Minimum interval between pitch error compensation positions =
maximum feedrate (rapid traverse rate)/7500
Units:
Minimum interval between pitch error compensation positions:
mm, inch, deg
Maximum feedrate: mm/min, inch/min, deg/min
[Example] When the maximum feedrate is 15000 mm/min, the minimum interval
between pitch error compensation positions is 2 mm.
If setting a magnification causes the absolute value of the
compensation amount at a compensation position to exceed 100,
enlarge the interval between the compensation positions by using a
multiple calculated as follows:
Multiple = maximum compensation amount (absolute value)/
128 (Round the remainder up to the nearest integer.)
Minimum interval between pitch error compensation positions =
Value obtained from the above maximum feedrate × multiple
Examples of parameter setting
[Example 1] For linear axis
• Machine stroke: -400 mm to + 800 mm
• Interval between the pitch error compensation positions: 50 mm
• No. of the compensation position of the reference position: 40
If the above is specified, the No. of the farthest compensation point in
the negative direction is as follows:
No. of the compensation position of the reference position -
(Machine stroke length in the negative direction /
Interval between the compensation points) + 1
= 40 - 400/50 + 1
=33