B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 579 -
8323
Maximum allowable difference between master axis and slave axis position
deviations
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets the maximum allowable difference between the
master axis and slave axis position deviations. If a position deviation
difference exceeds the value specified in this parameter, an alarm
(No.213) is issued.
Set this parameter with a master axis. If 0 is specified in this parameter,
no position deviation difference check is made.
8325
Maximum compensation value for synchronization compensation function
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets the maximum compensation value for
synchronization compensation function. If a compensation value
exceeds the value specified with this parameter, a servo alarm
(No.407) is issued.
Specify a master axis for this parameter. To enable this parameter, set
bit 7 (SOFx) of parameter No.8303 to 1.
8326
Difference between master axis and slave axis reference counters
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] -99999999 to 99999999
The difference between the master axis reference counter and slave
axis reference counter (master axis and slave axis grid shift) is
automatically set when automatic setting for grid positioning is
performed. Then, the difference is transferred together with an
ordinary grid shift value to the servo system when the power is turned
on.
This parameter is set with a master axis.