4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 522 -
Number of the axial feed axis for a helical gear
7719
[Data type] Byte
[Valid range] 1, 2, 3 to number of controlled axes
This parameter is valid when bit 1 (HBC) of parameter No. 7704 is set
to 1.
This parameter sets the ordinal number of the axial feed axis for a
helical gear. If a value not within the valid data range is set in this
parameter, the second axis is selected.
NOTE
1 If 0 is set in parameter No. 7719, the setting of
parameter No. 7709 is used. If 0 is set also in
parameter No. 7709 at this time, the second axis is
used as the number of the axial feed axis for a
helical gear.
2 Rewrite this parameter when hob synchronous
control is canceled. Even if this parameter is
rewritten during hob synchronous control (G81.4),
the new setting of this parameter does not become
valid until hob synchronous control is canceled
then is restarted.
#7 #6 #5 #4 #3 #2 #1 #0
7730 RTRx
[Data type] Bit axis
RTRx Retraction function is:
0 : Disabled for each axis.
1 : Enabled for each axis.
7740 Feedrate during retraction for each axis
[Data type] 2-word axis
[Unit of data, valid data range]
Valid data range
Input increment Units of data
IS-B IS-C
Metric machine 1 mm/min 30 to 240000 6 to 100000
Inch machine 0.1 inch/min 30 to 96000 6 to 48000
This parameter sets the feedrate during retraction for each axis.