4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 164 -
FO2 The second FSSB I/O unit is:
0 : Not used.
1 : Used.
NOTE
1 On the FSSB, an FSSB I/O module and separate
detector interface unit (pulse module) are handled
as units of the same type. The term "first unit" or
"second unit" used in the descriptions here
represents the ordinal number of a unit counted
without making a distinction between FSSB I/O
modules and separate detector interface units. For
example, suppose that one FSSB I/O module and
one separate detector interface unit are used and
that the separate detector interface unit is
connected on the FSSB closer to the CNC and the
FSSB I/O module is connected on the FSSB farther
from the CNC. In this case, the FSSB I/O module is
the "second unit".
2 An FSSB I/O module can also be used according
to the conventional setting method (setting using
bits 4 and 5 of parameter No. 1905, parameter No.
1936, and parameter No. 1937). When bits 4 and 5
of parameter No. 1903 are used, bits 4 and 5 of
parameter No. 1905, parameter No. 1936, and
parameter No. 1937 need not be set.
#7 #6 #5 #4 #3 #2 #1 #0
1904 DCNx DSPx
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit axis
DSPx
0 : Two axes use one DSP. (Ordinary axes)
1 : One axis uses one DSP. (Axes such as a learning control axis)
NOTE
Parameter No.1904 is set on the FSSB setting
screen. So, parameter No.1904 should not have to
be specified directly. This parameter need not be
set in FSSB manual setting 2 mode.