4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 476 -
#7 #6 #5 #4 #3 #2 #1 #0
7052 NMI
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit axis
NMI Set this parameter as indicated below.
NMI
• Axis for which bit 7 (NAHx) of parameter No. 1819 is set to 1 (for
not using advanced preview feed forward)
• Axes used for the function below when the servo FAD function is
not used:
- PMC axis
- Cs axis
- Index table indexing axis set for follow-up (fourth axis)
1
When the servo FAD function is used 0
#7 #6 #5 #4 #3 #2 #1 #0
7053
AIP NAN
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
NAN G5.1Q1 specifies:
0 : AI nano contour control
1 : AI contour control
AIP When AI contour control is exercised, stroke limit check before move
is:
0 : Disabled.
1 : Enabled.
NOTE
Stroke limit check before move needs to be
enabled (with bit 7 (PLC) of parameter No. 1301