4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 518 -
#7 #6 #5 #4 #3 #2 #1 #0
7703
LFS ARO ARE ERV
[Data type] Bit
ERV During EGB synchronous control, feed per revolution is performed:
0 : For feedback pulses.
1 : For pulses converted to the feedrate for the workpiece axis.
NOTE
When this parameter is set to 1, a value needs to
be set in parameter No. 7711.
ARE When the EGB alarm retract function is used, retract operation is
performed:
0 : During EGB synchronous control or automatic operation
(OP<F000#7> = 1).
1 : During EGB synchronous control. (Retract operation is not
performed even during automatic operation if EGB synchronous
control is not in progress.)
ARO When the EGB alarm retract function is used, retract operation is
performed:
0 : During EGB synchronous control.
1 : During EGB synchronous control and automatic operation
(OP<F000#7> = 1).
ARE ARO Retract operation
0 0
0 1
During EGB synchronous control or automatic
operation
1 0 During EGB synchronous control
1 1
During EGB synchronous control and automatic
operation
NOTE
This parameter is valid when bit 1 (ARE) of
parameter No. 7703 is set to 1.
LFS For inter-spindle synchronous control under spindle leaning control:
0 : The simple electric gear box (EGB) is used.
1 : Flexible synchronous control (FSC) is used.
NOTE
This parameter is invalid if leaning control is not
used.