B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 15 -
4.2.1 Parameters Common to all Channels
0024
Port for communication with the PMC ladder development tool (FANUC
LADDER-III)
This parameter can also be set on the “Setting screen”.
[Data type] Byte
This parameter sets the port to be used for communication with the
PMC ladder development tool (FANUC LADDER-III).
0 : According to the setting on the PMC online screen
1 : RS-232C serial port 1 (JD36A)
2 : RS-232C serial port 2 (JD36B)
10 : High-speed interface (HSSB (COP7) or Ethernet)
11 : High-speed interface or RS-232C serial port 1
12 : High-speed interface or RS-232C serial port 2
#7 #6 #5 #4 #3 #2 #1 #0
0100 ENS IOP ND3 NCR CRF CTV
[Data type] Bit
CTV: Character counting for TV check in the comment section of a
program.
0 : Performed
1 : Not performed
CRF EOB (end of block) to be output in the ISO code:
0 : Depends on the setting of bit 3 (NCR) of parameter No. 100.
1 : is "CR""LF".
NOTE
The EOB output patterns are as shown below:
NCR CRF EOB output format
0 0 "LF" "CR" "CR"
0 1 "CR" "LF"
1 0 "LF"
1 1 "CR" "LF"
NCR Output of the end of block (EOB) in ISO code
0 : LF, CR, CR are output.
1 : Only LF is output.