4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 504 -
4.58 PARAMETERS OF ROTARY TABLE DYNAMIC FIXTURE
OFFSET
#7 #6 #5 #4 #3 #2 #1 #0
7570
FK1 FTP
[Data type] Bit
FTP Fixture offset type setting
0 : Movement type
(The tool moves when the fixture offset changes.)
1 : Shift type
(The tool does not move when the fixture offset changes.)
FK1 When bit 7 (KEY) of parameter No. 3290 is set to 0, input of fixture
offset data using MDI keys is:
0 : Disabled when signal KEY1 is set to 0 or enabled when the
signal is set to 1.
(Same as for the input enable conditions for the tool offset value)
1 : Enabled when signal KEY1 is set to 0 or disabled when the
signal is set to 1.
(Inverse of the input enable conditions for the tool offset value)
#7 #6 #5 #4 #3 #2 #1 #0
7575
FAXx
[Data type] Bit axis
FAXx Axis-by-axis fixture offset is:
0 : Disabled.
1 : Enabled.