B-63484EN/05 3.CREATING AND EDITING SEQUENCE PROGRAMS
- 105 -
3.3.28 Automatic Input of Timer, Counter, Rising/Falling-edge
Numbers
This function automatically inputs the unused numbers for the
parameters of functional instructions during ladder editing of offline
mode and online mode. With this function, you can omit your
operation to find out the unused parameter numbers.
Supported PMC models
Supported
30i/31i/32i-A Extended function
30i/31i/32i-A (*1)
*1: This function can be used when ladder edit has selected the
interface of one pane; "Editing ladder diagram on display
window". This function cannot be used when ladder edit has
selected the interface of two panes; "Display Window" and "Edit
Window".
Supported instructions
The 1st parameter of the following functional instructions is the target
of automatic input.
SUB3(TMR)
SUB24(TMRB)
SUB77(TMRBF)
SUB5(CTR)
SUB56(CTRB)
SUB57(DIFU)
SUB58(DIFD)
Operation
1 Move cursor to the 1st parameter and push the [F6] key. The
unused parameter number will be input.
Fig. 3.3.28