B-63484EN/05 12.ERROR MESSAGES
- 409 -
Error code Message Cause/action
N:E-3300 Signal trigger unavailable
The user switched from online editing to the signal trigger stop
function.
N:E-3302 Reject Signal trigger
The user switched to online editing during signal trigger
execution.
N:E-3307
Cannot be changed Signal trigger is
executing
The user attempted to modify parameter settings during signal
trigger execution.
N:E-3390 Program is running
N:E-3410 Function param is out of range
N:E-6000
Signal Analysis function is not
supported
The PMC is of a type that does not support the signal analysis
function.
N:E-6001 Signal Trace function is running
During signal trace function execution, the signal analysis
function cannot be executed.
N:E-6002 Address Error A specified address is invalid.
N:E-6003 No Trigger Address
When the condition is <Trigger-ON> or <Trigger-OFF>, set a
trigger address.
N:E-6004
[About]/[Before] is illegal on [Start]
selected
When the condition is <Start>, <About> and <Before> cannot be
selected as a trigger mode.
N:E-6005 No Signal Address No sampling address is set.
N:E-6006 Sampling Time Error: An invalid sampling time is set.
N:E-6041 The communication to PMC is not ready The connection with the NC is disconnected.