B-63484EN/05 12.ERROR MESSAGES
- 399 -
Error code Message Cause/action
I:W-4202
The coil number specification of COM
instruction is not allowed.
The end of a COM instruction control range cannot be defined
using the number of coils. The specification of the number of coils
is ignored, and the end of a COM instruction control range is
determined based on the COME instruction.
I:W-4203
The coil number specification of JMP
instruction is not allowed.
The end position of a jump cannot be defined using the number
of coils. The specification of the number of coils is ignored, and
the end position is determined based on the JMPE instruction.
I:W-4204 Unused NET COMMENT pointer found.
A ladder program includes a pointer to a lost net comment
character string. The pointer is not output to a memory card
format file.
I:W-4400 There is no step sequence program.
A step sequence program is empty. The step sequence program
is not output to a memory card format file.
I:W-4500
The symbol data which could not be
display on the CNC was replaced with
space code.
Symbol data includes special characters that cannot be displayed
by the CNC. Those characters only are replaced with blank
characters.
I:W-4501
The comment data which could not be
display on the CNC was replaced with
space code.
Comment data includes special characters that cannot be
displayed by the CNC. Those characters only are replaced with
blank characters.
I:W-4502
Comment data size exceeds 64KB.
Symbol/comment data is not converted to
the Memory card format file.
The total number of comment data characters exceeded 65535.
None of the symbols/comment data is output to a memory card
format file.
I:W-4503
The character * in the comment may not
be displayed on the CNC.
The comment uses a character code not available to the CNC
and, therefore, may not be displayed.
I:W-4504
Double-sized space character in
comment was changed to two
single-sized speces.
e comments uses a double-byte space character, and the
character is replaced by two single-byte space characters.
I:W-4505 Too long strings for symbol data.
A symbol that exceeds the character length limit (six characters)
is found, and is deleted. (The comment remains valid.)
I:W-4570
The message data which could not be
display on the CNC was replaced with
space code.
Message data includes special characters that cannot be
displayed by the CNC. Those characters only were replaced with
blank characters.
I:W-4600 Unreferenced subprogram ****.
The **** sub-program is not called from any program, but is
output to a memory card format file.
I:W-4601 $ number * is duplicated.
I:W-6500 Address is illegal.
I:W-7500
The original symbol may be unable to
display by decompiling.
I: W-7551
Assignment was started from address
boundary.
12.2.9 Decompile
Error code Message Cause/action
J:F-2100
Function code error
DATA:***************
SYSTEM:************
There is a mismatch between the function codes in a memory
card format file and the function codes of the system. DATA is for
the file side, and DATA is for the system side. Install the correct
system.
J:F-2101
PMC series is different from **** Memory
card format file.
The type of memory card format file **** differs from the type of a
selected program. Select a correct program.
J:F-2102 **** Memory card format file not found.
The specified memory card format file **** is not found. Prepare
a file.
J:F-2103 Mismatched password.
Execution is rejected because the password is incorrect. Enter
the correct password.