B-63324EN-1/03 OPERATION 7.ALARMS AND SELF DIAGNOSTC FUNCTIONS
- 201 -
Number selection
Specify data to be displayed by using a number.
Method 1
(1) Press the [NO. SEARCH] soft key.
(2) Key in the number of the data you want to display.
(3) Press the [EXEC] soft key.
Method 2
(1) Press the [NO. SEARCH] soft key.
(2) Key in the number of the data you want to display.
Explanations
With diagnosis numbers 1000 and 1001, you can check the CNC status
when a specified command does not appear to be executed. When each
diagnostic data is set to 1, the following status is indicated:
Table 7.1 (a) Status Indication When a Command Does not Appear to be Executed
No. Indication Internal status when 1 is indicated
1000 INPOSITION CHECK
FEEDRATE OVERRIDE 0%
JOG FEED OVERRIDE 0%
INTER/START LOCK ON
SPEED ARRIVAL ON
WAIT REVOLUTION
STOP POSITION CODER
FEED STOP
In-position check is in progress.
The feedrate override value is 0%.
The jog feedrate override value is 0%.
Interlock/start lock is on.
The CNC waits until the speed attained signal is turned on.
The CNC waits for the spindle one-rotation signal during
threading.
The CNC waits for position coder rotation during spindle feed
per revolution.
In the feed stop state.
1001 FOREGROUND READING
BACKGROUND READING
Foreground data is being input.
Background data is being input.
With diagnosis number 1010, you can check the status of the input
signals related to reset/feed hold operation. When each bit of the
diagnostic data is set to 1, the following status is indicated:
Table 7.1 (b) Reset Status Indication
No. Bit Indication Internal status when 1 is indicated
1010 0
1
2
3
ESP
RRW
ERS
RST
Emergency stop state
The reset & rewind signal is on.
The external reset signal is on.
The reset key is pressed.