12.INPUTTING/OUTPUTTING DATA OPERATION B-63324EN-1/03
- 540 -
Item name Parameter Option (parameter setting)
TV CHECK TVC(No.0000#0) ON (1)/OFF (0)
TV (COMMENT) CTV(No.0000#1) ON (0)/OFF (1)
IN/OUT CODE ISP(No.0000#2)
EIA(No.0000#4)
EIA
ISO
ASCII
(#2=0/1 ,#4 =1)
(#2=0 ,#4 =0)
(#2=1 ,#4 =0)
EOB CODE NCR(No.0000#3)
LF CR CR(0) ^LF(1)
F.G. INPUT
F.G. OUTPUT
B.G. INPUT
B.G. OUTPUT
(No.0020)
(No.0021)
(No.0022)
(No.0023)
RS232-C C1
RS232-C C2
RS232-C C3
MEMCARD
RMTBUF
RS422 C1
OPEN CNC1
OPEN CNC2
(1)
(2)
(3)
(8)
(10)
(13)
(15) (DNC operational interface)
(16) (UP LOAD/DOWN LOAD interface)
- RS-232C, RS422 SETTING
Set the communication conditions for each of RS-232C and RS-422
channels. The device type, number of stop bits, and baud rate are
specified using the following parameter sets and are allocated to
channels for which device numbers are set using parameters Nos. 5001
to 5003 and 5013.
Parameter set 1: parameters Nos. 5110, 5111, and 5112
Parameter set 2: parameters Nos. 5120, 5121, and 5122
:
Parameter set 9: parameters Nos. 5190, 5191, and 5192
Item name Parameter Setting
DEVICE
TYPE
(No.5110,5120,5130)
(No.5140,5150,5160)
(No.5170,5180,5190)
1 to 8
STOP BIT (No.5111,5121,5131)
(No.5141,5151,5161)
(No.5171,5181,5191)
1/2
BAUD RATE (No.5112,5122,5132)
(No.5142,5152,5162)
(No.5172,5182,5192)
1 to 12
( 50, 100, 110, 150, 200, 300, 600,
1200, 2400, 4800, 9600, 19200bps)
- [HINT]
Brief description of the item to which the cursor is positioned, such as
the possible settings.
Data setting
1) Enter MDI mode.
2) Use the cursor keys,
, to position the cursor on
the desired item.
3) Use the [SELECT +] and [SELECT -] soft keys to select the
desired setting.