12.INPUTTING/OUTPUTTING DATA OPERATION B-63324EN-1/03
- 538 -
12.2 SPECIFYING PARAMETERS REQUIRED FOR
INPUT/OUTPUT
Follow the procedure described below to specify the parameters related
to communication:
(1) On the setting parameter screen, enable parameter writing.
(2) On the communication setting screen, specify the parameters
related to communication.
12.2.1 Setting Parameter Screen
Follow the procedure described below to enable parameter writing:
(1) Place the system in MDI mode or in the emergency stop state.
(2) Follow either of the procedures described below to display the
setting parameter screen.
Method 1
Press the
SETTING
function key several times, until the setting
parameter screen appears.
Method 2
(1)
Press the
OFFSET
SETTING
function key.
(2)
Click the [SETTINGPARAM] soft key.
Fig. 12.2.1 Setting Parameter Screen
(3) Set PWE (bit 0 of parameter No. 8000) and PRA (bit 2 of
parameter No. 8000) to 1.