12.INPUTTING/OUTPUTTING DATA OPERATION B-63324EN-1/03
- 554 -
12.4.2 Inputting System Parameters
The following explains the operation for inputting the system
parameters to the memory of the CNC to a floppy disk.
Setup for input
(1) Select MDI mode.
(2) Enter the emergency stop status.
(3) Follow either of the procedures described below to display the
Parameter screen.
Method 1
Press the
SYSTEM
function key several times, until the
Parameter screen appears.
Method 2
(1) Press the
SYSTEM
function key.
(2) Press the [
PARAMETER
] soft key.
Execution of input
Method 1 (Neither the input file name nor number need be specified)
(1) Press the [READ] soft key.
(2) Press the [
PARAMETER] soft key.
Method 2 (The input file is specified with its file name)
(1) Press the [READ] soft key.
(2) Press the ["FILE NAME] soft key.
(3) Enter a file name.
(4) Press the [FILE NAME"] soft key.
(5) Press the [
PARAMETER] soft key.
Method 3 (Specified with its file number (one of three methods))
(1) Press the [READ] soft key.
(2) Press the [(FILE#)] soft key.
(3) Enter a file number.
(4) Press the [
PARAMETER] soft key.
Method 4 (Specified with its file number (two of three methods))
(1) Press the [READ] soft key.
(2) Press the
N
address key.
(3) Enter a file number.
(4) Press the [
PARAMETER] soft key.
Method 5 (Specified with its file number (three of three methods))
(1) Press the
N
address key.
(2) Enter a file number.
(3) Press the [READ] soft key.