B-63324EN-1/03 OPERATION 9.SETTING AND DISPLAYING DATA
- 327 -
- Termination of setting
Upon completion of parameter setting, set bit 0 (PWE) of parameter No.
8000 for allowing setting input to 0.
Selecting a group
On the group selection screen, the parameters of a desired group can
easily be displayed.
- Group selection screen
Fig. 9.6 (b) Group Selection Screen
- Displaying the group selection screen
On the parameter screen, press the [SELECTGROUP] soft key.
- Positioning the cursor
Position the cursor to the group you want to display.
Method 1
Using the cursor keys , position the cursor.
Method 2
(1) Press the [NUMBER SEARCH] soft key.
(2) Key in the number of the group you want to display.
(3) Press the [EXEC] soft key.
Method 3
(1) Key in the number of the group you want to display.
(2) Press the [NUMBER SEARCH] soft key.
- Terminating the group selection
Pressing the [SELECT END] soft key terminates the group selection
screen to return to the parameter screen.