9.SETTING AND DISPLAYING DATA OPERATION B-63324EN-1/03
- 364 -
Method 2
(1) Select MDI mode.
(2) Key in a desired counter value.
(3) Press the [PRESET COUNT] soft key.
- Clearing execution data
All execution data of a specified group up to the current point can be
cleared.
Method 1
(1) Press the [CANCEL] soft key.
(2) Enter a group number.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a group number.
(2) Press the [CANCEL] soft key.
- Skipping of tools
Among the tools registered in a specified group, the tool to be selected
next is skipped.
Method 1
(1) Press the [SKIP] soft key.
(2) Enter a group number.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a group number.
(2) Press the [SKIP] soft key.
Tool life management (group editing)
Tool life management data can be edited when MDI mode is set, and
the automatic operation stop state, automatic operation halt state, or
reset state (not during a reset) is set. However, tool life management
data cannot be edited while data is being set by a program. The
following editing operations are possible:
- Setting of service life count type, service life values, counter, and
tool data (T code, H code, D code)
- Addition of tool groups
- Addition of tool numbers (T code)
- Deletion of tool groups
- Deletion of tool data (states, T code, H code, D code)
- Setting for tool skip
- Setting for tool clearing (restart of service life)