B-63324EN-1/03 OPERATION 9.SETTING AND DISPLAYING DATA
- 361 -
Count override : When the tool life count override signal is
disabled (with bit 3 (LFV) of parameter No.
7401 set to 0), 1.0 times is indicated.
- Data (B)
The set service life values, current tool life counter values, and
registered tool numbers (in order of use) of each group are displayed.
When the time-based service life count type is specified, the display
and setting units used for set service life values and tool life counters is
determined by bit 0 (FCO) of parameter No. 7403, as follows:
Bit 0 (FCO) of parameter No. 7403 0 1
Unit of display and setting of service life
values and service life counters
1 minute 0.1 minute
The table below indicates the meaning of a mark prefixed to each tool
number:
Tool state Used Not used
Service life remains. @ No indication
Skip # #
Service life has expired. @/*(*1) *
*1 When bit 2 (EMD) of parameter No. 7401 is set to 0, @
continues to be indicated until the next tool is selected, even
if the service life has expired.
The service life counter indicates a count value for a tool marked with
@. An asterisk (*) is displayed for a tool when the group to which the
tool belongs is next specified.
One page displays information for multiple groups. The number of
groups displayed on one page depends on the number of groups and the
number of tools in each group.
- Data (C)
Group numbers for which the tool change signal is output are displayed.
If one screen cannot display all of those group numbers, ---> is
displayed. In other cases, **** is displayed at the end.