3.MANUAL OPERATION OPERATION B-63324EN-1/03
- 64 -
Restrictions
- Moving the tool again
Once the REFERENCE POSITION RETURN COMPLETION
LED lights at the completion of reference position return, the tool
does not move unless the REFERENCE POSITION RETURN
switch is turned off.
- Reference position return completion LED
The REFERENCE POSITION RETURN COMPLETION LED is
extinguished by either of the following operations:
- Moving from the reference position.
- Entering an emergency stop state.
- The distance to return to reference position
For the distance (Not in the deceleration condition) to return the
tool to the reference position, refer to the manual issued by the
machine tool builder.