7.ALARMS AND SELF DIAGNOSTC FUNCTIONS OPERATION B-63324EN-1/03
- 220 -
(2) To input periodic maintenance data, display the item setting
screen. To input the machine menu, display the item
selection menu screen.
(3) Press the [READ] soft key.
(4)
Press the address key.
(5) Enter a file number.
(6) Press the [PERIODMAINTE] soft key.
Method 5 (The input file is specified with its file number (three of three
methods))
(1) Select EDIT mode.
(2) To input periodic maintenance data, display the item setting
screen. To input the machine menu, display the item
selection menu screen.
(3)
Press the address key.
(4) Enter a file number.
(5) Press the [READ] soft key.
NOTE
1 If an item name is omitted for an item number in the
input data, the data corresponding to that item
number is deleted.
2 When data is input from a FANUC Floppy Cassette,
FANUC FA Card, or FANUC Handy File, the input file
can be specified using a file name or file number.
3 When data is input from a memory card, the input file
can be specified using a file name.
Outputting setting items
Method 1 (Neither the output file name nor number need be
specified j
(1) Select EDIT mode.
(2) To output periodic maintenance data, display the item setting
screen. To output the machine menu, display the item
selection menu screen.
(3) Press the [PUNCH] soft key.
(4) Press the [PERIODMAINTE] soft key.
Method 2 (The output file is specified with its file name j
(1) Select EDIT mode.
(2) To output periodic maintenance data, display the item setting
screen. To output the machine menu, display the item
selection menu screen.
(3) Press the [PUNCH] soft key.
(4) Press the ["FILE NAME] soft key.
(5) Enter a file name.
N
N