FANUC Power Mate i -MODEL H
CONNECTION MANUAL(FUNCTION)
M-code direct output function
(High Response Function)
13/16
SHEET
Parameter
Data no Data
7410 M-code 1 for direct signal output function
7411 M-code 2 for direct signal output function
7412 M-code 3 for direct signal output function
(Data type): Word
(Valid data range): The number of the M-code for direct signal output is
specified.
The M-code with special meaning like below are not used.
M00,M01,M02,M30,M98,M99,M800M999 and
M90000000M99999999
These M-codes can be used only in high response mode.
Data no Data
7415 Output address 1 for M-code for direct signal output function
7416 Output address 2 for M-code for direct signal output function
7417 Output address 3 for M-code for direct signal output function
(Data type): Word
(Valid data range): The Y address of PMC to output direct signals are
specified.
From 1000 to 1002 (Y address of built-in I/O)
It is not necessary to specify the character “Y”. Only
numerical value should be set here. The correspondence
between the M-code and the direct signals are decided like
below.
No.7415 corresponds to No.7410.
No.7416 corresponds to No.7411.
No.7417 corresponds to No.7412.
Note) When this parameter is set, the power must be turned
off before operation is continued.
These parameters are effective when direct signal output
function is used in high response mode.