4/15
EDIT
DATE
DESIG.
DESCRIPTION
CUST.
SHEET
TITLE
DRAW.NO.
FANUC Power Mate i-MODEL H
OPERATOR’S MANUAL
Custom Macro in the high response mode
B-63174EN/02-02
0126
The number for DO and END is not correct.
Example)WHILE[#1200000 EQ 1] DO4 ;;
END4 ;;
0128 The illegal macro sequence number is specified.
Example) GOTO 90000 ;;
N90000 ;;
1011 The macro variable after P in the G31 block is specified.
Example) G90 G31 P#1000000 X0 ;;
1024 This error occurs when one of the following commands is specified.
• The macro variable ‘#’ is specified for M code group number.
Example) 50 P#1000000 ;;
• The macro variable ‘#’ is specified for the parameter of the M
code output function.
Example) 40 P#1000000 Q1 ;;
1030 The macro sentence is not available because of the parameter
setting.
1060 The operator for the arithmetic or logic operation (=) is not correct.
Example) #1000000 = #1000000 ABS[#1200000] ; ;
1061 The number of the sequence number in a program is 1001 or over.
1062 The number of terms in the right of the operator is 2 or over.
Example) #1000000 = #1200000 + #1200000+ #1200000 ;;
1063 The modal commands are not specified just after the ‘N’ or WHILE
statement.
Example) GOTO 1 ;;
N1 X1000 ;;