External Punch
Start Data
Number Signal
EDG00-EDG15
< G252-G253 >
(Classification) Input signal
(Function) Specify the value according to the start number of each data in
16 bit binary, when macro variable, diagnosis data or PMC data are
output.
(Data range: 0 – 65535)
The setting value is as follows.
・In case macro variable
Specify the start number of macro variable to be output.
・In case diagnosis data
[In case the parameter No.8761#0(EIB)=0 (the former way)]
Specify the value that is the sum of the output start number
and 20000.
[In case the parameter No.8761#0(EIB)=1 (the enhanced way)]
Specify the output start number.
・In case PMC data
Specify the value according to the following table.
Range of output start address
(In case PMC-SB5)
Range of output start address
(In case PMC-SB6)
The value to set to
EDG00-EDG15
G0000 to G0255 G0000 to G0511 21000+Start number of G address
F0000 to F0255 F0000 to F0511 23000+Start number of F address
Y0000 to Y0127 Y0000 to Y0127 25000+Start number of Y address
Y1000 to Y1063 Y1000 to Y1063 25000+Start number of Y address
X0000 to X0127 X0000 to X0127 27000+Start number of X address
X1000 to X1063 X1000 to X1063 27000+Start number of X address
A0000 to A0024 A0000 to A0124 29000+Start number of A address
R0000 to R1499 R0000 to R2999 30000+Start number of R address
R9000 to R9117 R9000 to R9199 30000+Start number of R address
T0000 to T0079 T0000 to T0299 40000+Start number of T address
K0000 to K0019 K0000 to K0039 or
K0900 to K0909
41000+Start number of K address
C0000 to C0079 C0000 to C0199 42000+Start number of C address
D0000 to D2999 D0000 to D7999 43000+Start number of D address
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
30/40
APPROV.
FANUC LTD