11. PROGRAM COMMAND
B–63173EN–1/01
418
#7 #6 #5 #4 #3 #2 #1 #0
6000 SBM
[Data type] Bit
SBM Custom macro statement
0 : Not stop the single block
1 : Stops the single block
#7 #6 #5 #4 #3 #2 #1 #0
CLV6001 CCV TCS CRO PV5 PRT
[Data type] Bit
PRT Reading zero when data is output using a DPRNT command
0 : Outputs a space
1 : Outputs no data
PV5 Custom macro common variables
0 : Outputs custom macro common variables #500 through #599.
1 : Outputs custom macro common variables #100 through #199 and
#500 through #599.
CRO ISO code output using a BPRNT command or a DPRNT command
0 : Outputs only LF after data is output
1 : Outputs LF and CR after data is output
TCS Custom macro (subprogram)
0 : Not called using a T code
1 : Called using a T code
CCV Custom macro’s common variables Nos. 100 through 199
0 : Cleared to “vacant” by reset
1 : Not cleared by reset
CLV Custom macro’s local variables #1 through #33
0 : Cleared to “vacant” by reset
1 : Not cleared by reset
Parameter
D Setting for single block
stop
D Other settings