EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
Addition of display PMC screen in handy
operator’s panel
CONNECTION MANUAL
Function
B-63173EN-1/01-18
B-63173EN-1/01-18B-63173EN-1/01-18
B-63173EN-1/01-18
SHEET
4/4APPROV.
FANUC LTD
01 010220 New design
Note.
1. Symbol data can not be displayed.
2. Forced input/output function can not be used.
PMC SIGNAL STATUS MONIT RUN
ADDRESS 7 6 5 4 3 2 1 0
G0000 0 0 0 1 0 0 0 0
G0001 1 0 0 0 0 1 0 0
G0002 0 0 0 0 0 0 0 0
G0003 0 0 0 0 0 0 0 0
G0004 0 0 0 0 1 0 0 0
G0005 0 1 0 0 0 0 0 0
G0006 0 0 0 0 0 0 0 0
G0007 0 0 1 0 0 0 0 0
G0008 0 0 1 1 0 0 0 1
G0009 0 0 1 0 1 0 1 0
>
[SEARCH][ ][ ][ ][ ]
Restricted items
When the handy operator's panel is used, the functions other than above mentioned
functions are restricted.
The following list shows some functions that can not be used on the handy operator's
panel.
1. Editing functions (editing ladder diagram, address allocation of I/O, message, symbols,
title and so on)
2. Ladder diagram display function
3. Trace function
4. Contents of memory display function
5. Signal wave forms display function