(3) Inputting/
outputting
macro variables
Be sure to select the enhanced way by setting the parameter
No.8761#0(EIB)=1.
(a) Inputting macro variables
① Turn the macro variable selection signal “EVAR” to “1” and turn
the other selection signals to “0”.
② Specify an input channel by the external I/O device control channel
selection signal, “EXIO1 and EXIO2”. When RS-232-C is selected,
set the value 0 or 1 to the parameter No.20. Set the parameters of
reader/puncher interface corresponding to the selected RS-232-C
channel.
③ Prepare an input file in the external device.
The data format in the file must meet with “the format of the
macro variable data” described later.
④ Specify the input file by the following.
When the file is input from a handy-file via RS-232-C, perform
heading file operation in the handy-file side.
When the file is input from a memory card, specify the input file
name by the external I/O device control file name selection signal,
“FLN00-FLN15”.
⑤ Turn the memory protect key “KEY2” to 1 only in case the
parameter No.3290#7(KEY)=0.
⑥ After the mode other than MDI mode is selected, input of macro
variables is started by turning on the external I/O device control
external read start signal, “EXRD”.
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
8/40
APPROV.
FANUC LTD