FANUC Power Mate i-MODEL H
Skip function for High-speed response function
B-63173EN-1/01-40
Caution
CAUTION
1 Disable feedrate override and automatic acceleration/
deceleration during moving axis by skip command to
improve the precision of the tool position when skip
signal is input. (if No.6200#7 SKF = 1, then effective)
2 When automatic acceleration/deceleration is effective
(the parameter SKF (No.6200#7) is set to “1”), block
skip by skip signal or torque limit is not performed
during decelerating.
Note
NOT
1 The skip cutting commands (G31P_) are all identical,
except that they correspond to different skip signals.
The tool moves along the specified axis until the SKIP
signal is set to “1” or the end point of the specified
movement is reached, while performing linea
interpolation. The feedrate is specified in the program.
2 When the measuring motion is made by utilizing the
skip signal, program a constant feedrate; otherwise, i
the feedrate changes, the measuring error will be
noticeable. With a constant feedrate, the maximum
measuring error can be calculated as follows:
ERRmax = Fm × ×
ERRmax: Maximum measuring error [mm]
Fm : Measuring feedrate [mm/min]
*1 The value becomes 9 when the skip signals, SKIPP1~
16<G0266,G0267>, are used. (Also it changes
according to the delay time of receiver or the
processing time of ladder program).
3 Maximum overtravel amount Qmax after the skip
signal has been turned to “1” is calculated by the
following: (In case that the parameter SSRT
(No.8680#1) is set to “0”)
Qmax = Fm × × ( 8 *
2
+ Tc + Ts )
Qmax : Maximum overtravel amount [mm]
Fm : Feedrate [mm/min]
Tc : Cutting time constant [ms]
Ts : Servo time constant [ms] (1/loop gain)
*2 The value becomes 12 when the skip signals, SKIPP1
~16<G0266,G0267>, are used. (Also it changes
according to the delay time of receiver or the
processing time of ladder program).
1
2
1
1000
1
60
5 *
1
1000
1
60