B–63173EN–1/01
3. MANUAL OPERATION
143
Rapid traverse
rate
Jog feed mode
or manual handle step feed mode
+J1
RT
1st axis move
Feedrate selected by manual
feedrate override signal
WARNING
After the power is turned on, the stroke limit function does
not work until the reference position return is completed.
During this period, the control unit ignores the RT signal, if
it is set to “1”, and keeps moving the tool at a feedrate
selected by the manual feedrate override signal. A
parameter RPD (No. 1401#0) can be specified so that the
rapid traverse is validated before the reference position
return is completed.
#7
*JV7G010
#6
*JV6
#5
*JV5
#4
*JV4
#3
*JV3
#2
*JV2
#1
*JV1
#0
*JV0
*JV15G011 *JV14 *JV13 *JV12 *JV11 *JV10 *JV9 *JV8
RTG019
+J8G100 +J7 +J6 +J5 +J4 +J3 +J2 +J1
–J8G102 –J7 –J6 –J5 –J4 –J3 –J2 –J1
#7
1002
#6 #5 #4 #3 #2 #1 #0
JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in jog feed, manual rapid
traverse and manual reference position return
0 : 1 axis
1 : Two axes for the Power Mate i–D and three axes for the Power Mate
i–H (in Power Mate i–D two–path control, only one axis on each path)
Signal address
Parameter