B–63173EN–1/01
2. PREPARATIONS FOR OPERATION
132
These signals are used to identify APC alarms that occur in the Power
Mate CNC.
[Classification] Output signal
[Function] This signal indicates that APC communication error (alarm 301) has
occurred.
1 APC communication error of 1st axis
2 APC communication error of 2nd axis
: :
: :
A P C M 1
[Output condition] The signal becomes 1 if:
– APC communication error occurs.
The signal is 0 if:
– APC communication error has not occurred.
[Classification] Output signal
[Function] This signal indicates that APC over time error (alarm 302) has occurred.
1 APC over time error of 1st axis
2 APC over time error of 2nd axis
: :
: :
A P O V 1
[Output condition] The signal becomes 1 if:
– APC over time error occurs.
The signal is 0 if:
– APC over time error has not occurred.
2.12
APC ALARM
CLASSIFICATION
SIGNALS
General
Signal
APC communication
error signal APCMn
<F236#0 to F243#0>
APC over time error
signal APOVn <F236#1
to F243#1>