B–63173EN–1/01
1. AXIS CONTROL
67
one master/slave axis pair is in sync, it is necessary to use parameters
ATEx (bit 0 of parameter No. 8303) and ATSx (bit 1 of parameter No.
8303).
1 Set bit 1 (ATS) of parameter No. 8302 to 1.
2 Enter ZRN mode (or JOG mode for reference position setting without
dogs), and move along the axis toward the reference position.
3 Motion along the master and slave axes stops automatically, and the
grid deviation is set in parameter No. 8316. At the same time, bit 1
(ATS) of parameter No. 8302 becomes 0, and a power–off request
alarm (No. 000) occurs.
4 Switch the power off then back on.
5 Perform ordinary reference position return.
NOTE
Parameter setting
When parameter ATS (bit 1 of parameter No. 8302) or ATSx
(bit 1 of parameter No. 8303) is set, parameter APZ (bit 4 of
parameter No. 1815) for the master and slave axes and
parameter No. 8316 become 0. If the operator specifies
parameter No. 8316 (MDI, G10L50), parameter ATE (bit 0
of parameter No. 8302) becomes 0.