B-63173EN-1/01-6
6/7EDIT
DATE DESIG. DESCRIPTION
ower
ate i-
The function o
assigning C executor’s screens to the
[CUSTOM/GRAPH] key.
Connection manual (function)
TITLE
DRAwNO CUST.
SHEET
01
990112 New design
8661 Size of variable areas
[Data type] Word
[Unit of data] KByte
[Valid data range] 0 to 59
Specify the size of the static variable areas that can be set by each task. Specify it by the
unit of 1 KByte. The maximum size is 59 Kbytes. And the total value of a SRAM Disk
size and this size should not exceed (usable SRAM size –1) KBtes (that is to say, 63
KBytes).
NOTE
When this value is changed, the contents of variable areas and a
SRAM Disk are initialized. The change of the set data becomes
effective after the next power on.
8662 Size of SRAM Disk
[Data type] Word
[Unit of data] KByte
[Valid data range] 4 to 63
Specify the size of a SRAM Disk. Specify it more than 4 KBytes by the unit of 1 KByte.
The maximum size is 63 KBytes. And the total value of a variable area and this size
should not exceed (usable SRAM size –1) KBtes (that is to say, 63 KBytes).
NOTE
When this value is changed, a SRAM Disk is initialized. The change
of the set data becomes effective after the next power on.
8663 Specification of time zone
[Data type] 2-word
[Unit of data] second
[Valid data range] –12*3500 to 12*3600
Specify the equation of time from Greenwich time by the unit of second. The value is –9
hours in japan (the value is –9*3600 = –32400).
NOTE
The change of the set data becomes effective after the next power
on.