External Punch Total
Data Number Signal
EDN00-EDN15
< G254-G255 >
(Classification) Input signal
(Function) Specify the total data number to be output in 16 bit binary, when
macro variable, diagnosis data or PMC data are output.
(Data range: 0 – 65535)
-----------------------------------------------------------------------------------------------------------------------------------------
External
Read/Punch Busy
Signal
RPBSY
< F053#2 >
(Classification) Output signal
(Function) This signal indicates that input/output of data triggered by the
external read or punch start signal is under way.
(Output condition) This signal becomes logical 1, when:
・The external read or punch start signal triggers input/output of
data
This signal becomes logical 0, when:
・Input/output operation triggered by the external read or punch
start signal ends either normally or abnormally (reset or
requested by the external read/punch stop signal EXSTP ).
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
31/40
APPROV.
FANUC LTD