EDIT
DATE DESIG
DESCRIPTION
B-63173EN-1/01-28
DRAW.NO.
CUST
TITLE
FANUC Power Mate i -MODEL H
CONNECTION MANUAL(FUNCTION)
M-code direct output function
(High Response Function)
16/16
SHEET
Alarm, diagnosis
In the following case, an alarm is generated and CNC comes to emergency
stop state when the power is turned on. The cause is displayed in diagnostic
data.
(1) The edition of the PMC control software is not the one to support the
function that allows CNC to access the Y address directly.
(2) In case that both “direct signal output function” and “pulse signal output
function” use the same bit of the same Y address on the built-in I/O.
• Alarm
Number
Message Contents
5800 The combination
of the system is
improper.
The function to be executed is
unavailable because the combination
of the system is improper.
As for the detail, refer to the
diagnosis screen. The data No.50 of
the diagnostic data shows the
improper system software. The data
No.60 shows the function that cannot
be used together.
• The detail of an alarm 5800 is displayed in the data No.50 and No.60 of
the diagnostic screen.
The detail of an alarm 5800
#7 #6 #5 #4 #3 #2 #1 #0
Diagnosis 50 PMC
The software to generate an alarm 5800 is informed.
PMC: The PMC control software is not proper.
Use the edition 03 or later of the ROM series 407B.
#7 #6 #5 #4 #3 #2 #1 #0
Diagnosis 60 HSO
The function to generate an alarm 5800 is informed.
HSO: As the specified Y address and bit on the built-in I/O overlaps with
the “pulse signal output function”, direct signal output function can
not be used.