(c) Via I/O Link on the master side
In case “Data input/output function via I/O Link – B (Master)”:
the parameter No.8761#0=0, IOLS<G92#1>=1
・ Start registration/collation of program or input of macro
variable/ parameter/diagnosis data (PMC) of the slave from
the slave device to the program storage area of the master
device in the mode other than MDI by to background editing
function via I/O Link
The selection of input/registration data depends on the
program number that is specified by the PMC functional
instruction, “WINDW” command.
・ There is other conditions to execute program registration/
collation. For instance, program registration/collation can not
be executed while the program with the same program number
is executing in foreground editing.
・ While data are reading/punching, “Read/punch busy signal
(RPBSY)” is turned to “1”.
・External read start signal (EXRD) is ignored, while background
editing operation is executed or Back ground editing signal
(BGACT) is turned to 1.
・ Input operation is interrupted, when reset is activated or
External read punch stop signal (EXSTP) is turned to 1.
・ External read start signal(EXRD) is ignored, while data
input/output operation or DNC operation is executing in
foreground editing.
・ In case program input, whether registration or collation
depends on the memory protect key KEY3<G046#5> (when the
parameter N0.3290#7=0) or KEY1<G046#3> (when the
parameter No.3290#7=1).
Note)
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
21/40
APPROV.
FANUC LTD