The feature of “Data input/output via I/O Link” functions are as follows.
① Data input/output via I/O Link (Master)
This function is executed when an operator operates a soft-key.
② Data input/output via I/O Link - B (Master)
In this function, “Data input/output via I/O Link (Master)” is
controlled by PMC ladder. And an operation is executed in the
background editing mode. A part of signals of this function are
shared with I/O device external control.
“Master function” manages the data of the slave, Power Mate, by
using a program storage area of the master.
③ Data input/output via I/O Link (Slave)
This function inputs/outputs the data of the slave, Power Mate,
from/to the master via I/O Link
The ways of start and data selection for each function are summarized in the
following tables.
Function Way of input/output
start
Way of data selection Necessary condition
Data input/output function via I/O
Link (Master)
Soft-key Program number PRM8761#0=0
Data input/output function via I/O
Link – B (Master)
Signal(EXRD,EXWT)
Specify a program
number by functionary
instruction of PMC
IOLS=1,
PRM8761#0=0
Data input/output function via I/O
Link (Slave)
Signal(EXRD,EXWT) Signal(EPRG etc.) IOLS=0, IOLNK=1,
PRM8761#0=0
External I/O device control
(via RS-232-C or memory card
slot)
Signal(EXRD,EXWT) Signal(EPRG etc.) IOLS=0,
In case PRM8761#0=0,
IOLNK=0,
RM8761#0=1, Specify
a
hannel by EXIO1,EXIO2
“
”
means the parameter No 8761
c
In case P
EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
Enhancement of External I/O device
control function
B-63173EN/01-32
SHEET
19/40
APPROV.
FANUC LTD