14. MEASUREMENT
B–63173EN–1/01
500
· When a block contains a G04, or G04Q1 to Q4 code for dwell, and the
skip signal is made applicable by parameter setting to the command, the
control unit stops dwell operation, and cancels any remaining dwell
time.
· The skip signal is monitored not for a rising edge, but for its state. So,
if a skip signal continues to be “1”, a skip condition is assumed to be
satisfied immediately when the next skip cutting or dwell operation is
specified.
#7
SKIPX000
#6 #5 #4 #3 #2 #1 #0
#7
SKIPX1000
#6 #5 #4 #3 #2 #1 #0
#7
G006
#6
SKIPP
#5 #4 #3 #2 #1 #0
#7
6202
#6 #5 #4 #3
1S4
#2
1S3
#1
1S2
#0
1S1
6203 2S4 2S3 2S2 2S1
6204 3S4 3S3 3S2 3S1
6205 4S4 4S3 4S2 4S1
6206 DS4 DS3 DS2 DS1
[Data type] Bit type
1S1~1S4, 2S1~2S4, 3S1~3S4, 4S1~4S4, DS1~DS4
Specify which skip signal is enabled when the skip command (G31, or
G31P1 to G31P4) and the dwell command (G04, G04Q1 to G04Q4) are
issued with the multi–step skip function.
The following table shows the correspondence between the bits, input
signals, and commands.
The settings of the bits have the following meanings:
0 : The skip signal corresponding to the bit is disabled.
1 : The skip signal corresponding to the bit is enabled.
Multi–step skip function
Command
Input
signal
G31
G31P1
G04Q1
G31P2
G04Q2
G31P2
G04Q2
G31P4
G04Q4
G04
SKIP, SKIPP 1S1 2S1 3S1 4S1 DS1
SKIP2 1S2 2S2 3S2 4S2 DS2
SKIP3 1S3 2S3 3S3 4S3 DS3
SKIP4 1S4 2S4 3S4 4S4 DS4
Signal address
Parameter