B–63173EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
251
RDR Dry run for rapid traverse command
0 : Disabled
1 : Enabled
1420 Rapid traverse rate for each axis
[Data type] Two–word axis
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 30 – 240000 30 – 100000
Inch machine 0.1 inch/min 30 – 96000 30 – 48000
Rotation axis 1 deg/min 30 – 240000 30 – 100000
Set the rapid traverse rate when the rapid traverse override is 100% for
each axis.
1424 Manual rapid traverse rate for each axis
[Data type] Two–word axis
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 30 – 240000 30 – 100000
Inch machine 0.1 inch/min 30 – 96000 30 – 48000
Rotation axis 1 deg/min 30 – 240000 30 – 100000
Set the rate of manual rapid traverse for each axis when the rapid traverse
override is 100% for each axis.
NOTE
If 0 is set, the rate set in parameter 1420 is assumed.
OPERATOR’S MANUAL
(B–63174EN)
II.5.2 Rapid traverse
[Unit of data]
[Valid data range]
[Unit of data]
[Valid data range]
Reference item