B–63173EN–1/01
1. AXIS CONTROL
74
8314 Allowable error in synchronization error check
[Data type] Word axis
Increment system IS–A IS–B IS–C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 32767
This parameter sets, in the detection unit, the allowable error when a
synchronization error check is made. The mechanical coordinates of the
master axis and slave axis are monitored. When a synchronization error
equal to or greater than the value set in this parameter is detected, servo
alarm No. 407 is issued, and the machine is stopped. Set this parameter
to the master axis. When 0 is set with this parameter, no synchronization
error check is performed.
8315 Maximum compensation value for synchronization compensation
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets the maximum compensation value for
synchronization. When a compensation value greater than the value set
in this parameter is used, servo alarm No. 410 is issued.
8316 Reference counter difference between the master and slave axes
(one master/slave axis pair under synchronous control)
NOTE
The system power must be turned off then back on in order
for this setting to become effective.
[Data type] Two–word
[Unit of data] Detection unit
[Valid data range] –99999999 to 99999999
This parameter is set to the reference counter difference between the
master and slave axes.
NOTE
Upon the completion of grid positioning, the reference
counter difference is set automatically. At the same time,
parameter ATS (bit 1 of parameter 8302) is reset to 0.
[Unit of data]