B–63173EN–1/01
A. INTERFACE BETWEEN CNC AND PMC
594
The address relationships between the Power Mate i–D/H and PMC
interface signals are shown below.
Y000~/Y1000~
(%Q00001
~/%QB00001~)
X000~/X1000~
(%I00001~
/%IB00001~)
CNC
G000~
(%QC00001~)
F000~
(%IC00001~)
PMC
MT
The addresses enclosed in parentheses (such as %QC00001) are those for
the PMC (PMC–SD) corresponding to IEC1131–3.
The details of the Power Mate i–D/H and PMC interface signal addresses
are listed below. In the list, #D represents signals dedicated to the Power
Mate i–D, while #H represents those dedicated to the Power Mate i–H.
The address of the PMC corresponding to IEC1131–3 is presented
together (Example 1).
Example 1:
#7
G005
#6
AFL
#2
SFIN#D
#1 #0
MFIN
Example 2 explains how to specify an address for referencing data on
a byte, word, or doubleword access basis.
Example 2:
To reference an M code as a byte (M00 to M07), word (M00 to M15),
or doubleword (M00 to M31), specify F010 (or, for the PMC–SD,
%IC81).
M07
#7
F010
#6
M06
#2
M02
#1
M01
#0
M00
M15F011 M14 M10 M09 M08
M23F012 M22 M18 M17 M16
M31F013 M30 M26 M25 M24
A.1
LIST OF ADDRESSES
A.1.1
Power Matei–MODEL
D/H List of Addresses