B–63173EN–1/01
3. MANUAL OPERATION
148
[Classification] Input signal
[Function] This signal selects the distance traveled per pulse from the manual pulse
generator during the manual handle feed or manual handle interrupt. It
also selects the distance traveled per step feed step.
The table below lists the signal–to–distance correspondence.
Travel distance
select signal for
manual handle
feed
Distance traveled
MP2 MP1
Manual handle
feed
Manual handle
interrupt
Step feed
0
0
1
1
0
1
0
1
Least input
increment1
Least input
increment10
Least input
incrementm*
1
Least input
incrementn*
1
Least command
increment1
Least command
increment10
Least command
incrementm*
1
Least command
incrementn*
1
Least input
increment1
Least input
increment10
Least input
increment100
Least input
increment1000
*1 Scale factors m and n are specified using parameter Nos. 7113 and
7114.
WARNING
Because the least input increment is used as the units for
manual handle and step feed, the same value represents a
different distance depending on whether the metric or inch
input system is used.
NOTE
See Section 3.3, “Manual Handle Interrupt” for manual
handle interrupts, and Section 3.1, “Jog Feed/Step Feed”
for step feed.
#7
HS2DG018
#6
HS2C
#5
HS2B
#4
HS2A
#3
HS1D
#2
HS1C
#1
HS1B
#0
HS1A
G019 MP2 MP1 HS3D HS3C HS3B HS3A
Manual Handle Feed
Amount Selection Signal
MP1, MP2<G019#4, 5>
(Incremental Feed
Signal)
Signal address