B–63173EN–1/01
9. SPINDLE SPEED FUNCTION
319
#7 #6 #5 #4 #3 #2 #1 #0
3701 ISI
[Data type] Bit
ISI Specifieds whether the serial spindle interface is used.
0 : Used
1 : Not used
NOTE
This parameter is enabled only when the serial spindle
interface option is provided. The parameter is used when
the CNC is started after serial spindle interface control is
temporarily disabled during startup adjustment of the CNC.
This bit should normally set to be 0.
No. 4000 to 4351: S1 → For 1st serieal spindle
The above parameters are on the CNC, but actually they are used for the
spindle control unit of serial spindle.
For details of these parameters, refer to the following manual:
FANUC AC SPINDLE MOTOR α series PARAMETER MANUAL
(B–65160E)
FANUC CONTROL MOTOR α series MAINTENANCE MANUAL
(B–65165E)
Parameter
D Connection of serial
spindle control unit
D Parameters of serial
spindle control unit