B–63173EN–1/01
2. PREPARATIONS FOR OPERATION
129
These signals are used to identify alarms that occur in the Power Mate
CNC.
[Classification] Output signal
[Function] This signal indicates that P/S alarm 100 (PARAMETER WRITE
ENABLE) has occurred.
[Output condition] The signal becomes 1 if:
– P/S alarm 100 occurs.
The signal is 0 if:
– P/S alarm 100 has not occurred.
[Classification] Output signal
[Function] This signal indicates that P/S alarm 000 (PLEASE TURN OFF POWER)
has occurred.
[Output condition] The signal becomes 1 if:
– P/S alarm 000 occurs.
The signal is 0 if:
– P/S alarm 000 has not occurred.
[Classification] Output signal
[Function] This signal indicates that P/S alarm 101 (PLEASE CLEAR MEMORY)
has occurred.
[Output condition] The signal becomes 1 if:
– P/S alarm 101 occurs.
The signal is 0 if:
– P/S alarm 101 has not occurred.
2.11
ALARM
CLASSIFICATION
SIGNALS
General
Signal
P/S Alarm 100 signal
ALPS1 <F250#0>
P/S Alarm 000 signal
ALPS2 <F250#1>
P/S Alarm 101 signal
ALPS3 <F250#2>